Table information for 'specphot.rcsed_gasmet'

General

This table is available for ADQL queries and through the TAP endpoint.

Resource Description: Spectra and photometry of galaxies derived from cross-match between SDSS, GALEX, and UKIDSS catalogs

For a list of all services and tables belonging to this table's resource, see Information on resource 'mirror TAP service for the Reference Catalog of Galaxy SEDs (RCSED)'

Citing this table

To cite the table as such, we suggest the following BibTeX entry:

@MISC{vo:specphot_rcsed_g,
  year=2016,
  title={mirror {TAP} service for the Reference Catalog of Galaxy {SEDs} ({RCSED})},
  author={I. Chilingarian and I. Zolotukhin and I. Katkov and A.-L. Melchior},
  url={http://voparis-tap-astro.obspm.fr/tableinfo/specphot.rcsed_gasmet},
  howpublished={{VO} resource provided by the {PADC} {TAP} Server on voparis-tap-astro.obspm.fr}
}

Columns

Sorted by DB column index. [Sort alphabetically]

NameTable Head DescriptionUnitUCD
id Id Primary key N/A meta.id;meta.main
objid Objid N/A N/A N/A
mjd Mjd MJD of observation d time.epoch
plate Plate SDSS plate ID N/A meta.id
fiberid Fiberid SDSS fiber ID N/A meta.id
e_bv E_bv Intrinsic E(B-V) mag phot.color.excess
gas_oh_d16 Gas_oh_d16 Oxygen abundance of ionized gas (12 + log O/H) calculated using Dopita+16 calibration from Gaussian fit to emission lines N/A phys.abund.Z
gas_oh_d16_err Gas_oh_d16_err Error of oxygen abundance of ionized gas (12 + log O/H) calculated using Dopita+16 calibration from Gaussian fit to emission lines N/A phys.abund.Z
gas_oh_izi Gas_oh_izi Oxygen abundance of ionized gas (12 + log O/H) calculated using IZI calibration from Gaussian fit to emission lines N/A phys.abund.Z
gas_oh_izi_errlo Gas_oh_izi_errlo Lower error of oxygen abundance of ionized gas (12 + log O/H) calculated using IZI calibration from Gaussian fit to emission lines N/A stat.error;phys.abund.Z
gas_oh_izi_errhi Gas_oh_izi_errhi Upper error of oxygen abundance of ionized gas (12 + log O/H) calculated using IZI calibration from Gaussian fit to emission lines N/A stat.error;phys.abund.Z
q_izi Q_izi Ionization parameter calculated using IZI calibration from Gaussian fit to emission lines N/A phys.ionizParam.rad
q_izi_errlo Q_izi_errlo Lower error of ionization parameter calculated using IZI calibration from Gaussian fit to emission lines N/A stat.error;phys.ionizParam.rad
q_izi_errhi Q_izi_errhi Upper error of ionization parameter calculated using IZI calibration from Gaussian fit to emission lines N/A stat.error;phys.ionizParam.rad

Columns that are parts of indices are marked like this.

Other

The following services may use the data contained in this table:

VOResource

VO nerds may sometimes need VOResource XML for this table.

Copyright and such: Free to use.